Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station

Product Details
Customization: Available
Type: Fiber Optic Production Machine
Wiring Devices: Fiber Insertion Loss Tester
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Years of Export Experience
The export experience of the supplier is more than 10 years
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
  • Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
  • Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
  • Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
  • Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
  • Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Find Similar Products
  • Overview
  • Patch Cord Fiber Polishing Solution
  • Neofibo : Your Reliable Supplier
  • Products Description
  • Specification
  • About Us
  • FAQ
Overview

Basic Info.

Model NO.
IL-650-2CH
Certification
CE, ISO
Condition
New
Light Source Wavelength
650nm
Light Source Power
1+/-0.2MW
Optical Power Meter Wavelength
650nm
Measurement Range (dBm)
-30~+3
Uncertainties
±3%
Display Resolution
Linearity: 2 Decimal Places; Relative Measurement:
Light-Emitting Device (LED)
Ld
Negative Return Loss Fiber
Optical Return Loss Meter
Return Loss Measurement
Return Loss
Insertion Loss and Return Loss
Insertion Vs Return Loss
Optical Fiber Inspector Visible Core
Fiber Insertion Loss and Back Reflection Tester
Fiber Insertion Loss Tester
Insertion Loss in Optical Fiber
Optical Waveguide Insertion Loss
Optical Fiber Connector Insertion Loss
Measuring Fiber Optic Insertion Loss
Insertion Loss Fiber Optic
Fiber Optics What Test Insertion Loss
Insertion Loss for Fiber Optics
Transport Package
Carton
Specification
30X32X18 cm
Trademark
Neofibo
Origin
Shenzhen China

Product Description

Patch Cord Fiber Polishing Solution
 
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
 
Neofibo : Your Reliable Supplier
 
* 16+ year Manufacturing Experience for OEM/ODM polishing program
* Independent research and development patent - Neoholder®
* Products have CE, ROHS certification 
* Support online video synchronization inspection machine
* Equipment test report and operation guide can be provided 
* SGS certified factory, delivery speed and secure,50 units in stock
* 30 days quality problems can be returned
 
Products Description
 
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station


Description:
It is used to measure the access loss of optical fiber at 650nm wavelength, and is commonly used for testing the optical index of plastic fiber or special quartz fiber.
 
If you don't know how to choose the insertion loss & return loss test station, please feel free to contact the supplier.
 
Key Features:
Dual-channel light source with an output power of 1+/-0.2mW;
Dual-channel power meter, effectively measuring the loss of access fiber or link;
Dedicated to HFBR series jumper insertion loss measurement;
Can also be used for special quartz fiber optical fiber harness insertion loss measurement;
Convenient for wire harness manufacturers to digitally manage the optical indicators of the harness to ensure product qualification rate.
Click Here And View More >>>Go
 

To know more products, please check quick links below connected to our homepage. Feel free to contact us.

 


Helpful Links
For instant communication, please click here
For our catalogs, please click here
For our home page, please click here

 
Specification

Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Technical Parameters:
Model IL-650-2CH
Light source wavelength 650nm
Light source power 1+/-0.2mW
Optical power meter wavelength 650nm
Measurement range (dBm) -30~+3
Uncertainties ±3%
Display resolution Linearity: 2 decimal places; Relative Measurement: 0.01dB
light-emitting device (LED) LD

Functional Description:
Markings Function
  Switching Wavelengths
Chan Switching channels (dual-channel exclusive function)
UNIT/ Measurement unit switching
REF/ Setting the relative power value and entering the relative value measurement mode
Menu/Enter Access to the menu screen
Cancel Deselect or opt out

Standard Configurations:
No. Description Qty
1 Dual-Channel Red Light Insertion Loss Test Station 1set
2 Product Manuals 1pcs
3 Power cable 1pcs
4 cleaning swab 1bag
5 Standardized Testing Line 2pcs

Instructions for use:
1. Change the wavelength value: Press λ to enter the change wavelength switching.
2. Power display switching: Press UNIT/ to switch the unit between dBm\mw\uw.
3. Relative power zeroing (loss test):
Zero the optical path insertion loss before measurement. Insert the end of the marker line into the optical power meter interface and press the REF key. Use the standard flange to connect the end of the marker with the measured end (start end) of the tested patch cord, and the other end (end) of the tested patch cord is inserted into the interface of the optical power meter. At this time, the differential loss measurement in the insertion loss display area is the insertion loss value at the beginning end of the patch cord under test.

Maintenance and care:
1. The optical power meter should work without obvious vibration.
2. Keep the sensor end face clean, do not use unclean, non-standard optical connectors.
3. When the optical power meter is not in use, please cover the dust cap.
4. Plug and unplug the optical connector carefully.
5. When cleaning the sensor surface, please use lens paper, add cleaning solution and then gently inserted along the circumference of the wipe.
6. Hold and put gently, to prevent the optical power meter fall, collision.
About Us
 
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
 We have 16+ years experience.could provide optic fiber production line and service for you. you can count on us to offer you the best solution.Neofibo is focusing on the field of fiber optic polishing solutions.We specialize in manufacturing fiber optic polishing machine, design various optical fiber connectors polishing fixtures, provide completed polishing process and materials for all kinds of fiber optic connectors.Neofibo can provide not only products, but also technical services and R & D support.
 
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
Il-650-2CH Featuring High Precision Measurement Comprehensive Data Logging User-Friendly Interface Dual-Channel Red Light Insertion Loss Test Station
 
 

FAQ


1.Polished ferrules could not reach required shape or quality.
(1)Film is used over 40 times.
(2)Water doesn't be used.
(3)Films are not cleaned completely.
(4)Ferrules and jig are not fixed correctly.
(5)The distance adjustment between screw top and Plane A is not correct.

2.Bad quality for the polished surface.
(1)Film is used over 40 times.
(2)Polishing liquid is not used.
(3)Film is dirty.
(4)Ferrules are not cleaned completely.
(5)Scraped by film when pulling out the ferrules.

3.How can we guarantee quality?
(1)Always a pre-production sample before mass production;
(2)Always final Inspection before shipment;

4.what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,DDP,DDU,Express Delivery
Accepted Payment Currency:USD,EUR,HKD,CNY;
Accepted Payment Type: T/T,L/C,Credit Card,PayPal,Western Union,Cash,Escrow;
Language Spoken:English,Chinese

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
People who viewed this also viewed